Control Panel Retrofits and Upgrades

Rebuild the panel you have, or swap it, planned around your shutdown window.

Signs your panel needs a retrofit

Panels rarely fail all at once. They send warnings first, and the most common warning is a part you cannot buy anymore. If your starters and relays only show up on surplus sites, every fault has become a sourcing problem. Watch for these signs on your plant floor:

  • Obsolete components. Discontinued PLCs, drives, and relays with no direct replacement on any distributor shelf.
  • Nuisance trips. Faults that clear on reset and never repeat the same way. Loose terminations, tired relays, and marginal power supplies are the usual causes.
  • Undocumented changes. Jumper wires, bypassed interlocks, and drawings that no longer match what is inside the enclosure.
  • Heat damage. Discoloured terminals, brittle insulation, contactors that smell cooked. Heat shortens the life of every component in the enclosure.

Two or more of these together is a strong case for a planned retrofit before the panel forces an unplanned one. A panel that fails on its own schedule always picks a worse time than you would.

Rebuild in place or swap the panel

There are two ways to fix a tired panel. Rebuild it in place, or build a new one and swap it. The right answer depends on the enclosure, the wiring, and how much downtime you can afford.

An in-place rebuild keeps the enclosure and the field wiring. Work happens in stages, one section of the backplane at a time, usually across several short outages. It suits panels with a sound enclosure, clean wire condition, and room to work. A full swap replaces the enclosure and everything in it. We build and test the new panel in our shop first, then land it in one planned cutover. Total time on your floor is shorter, but the single outage is longer.

Our rule of thumb is simple. If the enclosure is rusted, undersized, or heat damaged, or the wiring cannot be trusted, swap it. If the bones are good and the parts are the problem, rebuild in place.

Obsolete parts, crossed and modernized

Most obsolete parts have a modern equivalent. We cross-reference discontinued starters, relays, power supplies, terminal blocks, and I/O against current production parts, and we record every substitution on the drawings. Where a one-for-one cross does not exist, we redesign that circuit rather than force a fit.

When the PLC itself is end of life, the retrofit becomes a PLC migration, and we scope that as part of the same job. We program five platforms, Allen-Bradley, Schneider, Omron, Phoenix Contact, and Unitronics, so the replacement is chosen on merit, not habit. Existing logic is converted and tested against the as-found sequence in ladder logic or another IEC 61131-3 language that fits the job. A retrofit is also the right moment to move serial Modbus devices onto EtherNet/IP or PROFINET, so the new panel reports to your SCADA instead of sitting silent on the network.

Rewiring, relabelling, and real documentation

A retrofit is only as good as its wiring and its paper trail. Our Red Seal industrial electricians rewire to one consistent standard: ferruled terminations, wire numbers on both ends, and labels that match the drawings instead of someone’s memory.

Documentation runs in two states. As-found records capture the panel exactly as we opened it, including every jumper and undocumented change from the last twenty years. As-left records show what we changed and why. When we close the enclosure you get updated schematics, an I/O list, and a substitution log. The next person who opens that panel, ours or yours, starts from facts instead of folklore.

The work is engineering-led, with a B.Eng on staff, so drawing revisions are reviewed before they are issued, not sketched on the inside of the door.

QPS Certified mark

Built and tested under our QPS certification.

Cutovers on weekends and shutdown windows

Retrofits should happen when your plant is already down. We plan cutovers for weekends, holidays, and scheduled shutdown windows, and we pre-stage everything: panel built, program tested, labels printed, and the old-to-new wire map in hand before the first breaker opens.

That discipline matters in the Maritimes. Seafood plants get narrow windows between seasons. Sawmills and forestry operations concentrate their maintenance into planned shutdowns. Manufacturers in Halifax, Truro, Amherst, Moncton, Saint John, and Charlottetown often have exactly one weekend to get the work done, with no second chance until the next quarter. We are based in Dieppe, NB, and we plan travel, parts, and staffing around your window, not ours.

If a cutover hits trouble, the emergency line at 1-833-423-3367 reaches the same team that built the panel. Not a call centre. The people who have the drawings.

One team, and proof it worked

Design, panel build, code, install, and support come from one team here. The engineer who scopes your retrofit works beside the panel shop that builds it and the electricians who land it. Nothing gets thrown over a wall to a subcontractor, so nothing gets lost between the drawing and the enclosure.

We will not hand you invented numbers about what a retrofit saves, and you should be suspicious of anyone who does. We will help you measure it honestly instead. Pull your trip log and CMMS work orders for that panel over the past year. That is your baseline. Track the same data after the retrofit. A sound retrofit shows up as fewer unplanned stops, faster fault-finding because the labels match the drawings, and spare parts you can actually order when something does fail.

Start with an assessment. We inspect the panel, flag obsolete and heat-stressed components, and give you a written scope with the rebuild-or-swap call spelled out. Then get a retrofit quote and decide with real information in front of you.

Get a retrofit quote

Send specs,
get numbers

No pitch and no pressure: if a retrofit is not the right call for your panel, we will tell you that too.

This field is for validation purposes and should be left unchanged.
Voltage, enclosure, I/O count, application, quantity. Rough is fine.
Drop files here or
Accepted file types: pdf, dwg, dxf, jpg, png, zip, step, stp, Max. file size: 32 MB, Max. files: 5.
    Straight answers

    Common questions

    How much does a control panel retrofit cost?It depends on scope, and anyone quoting a number before opening the enclosure is guessing. The main cost drivers are the count of obsolete components, whether the PLC is being migrated, the condition of the wiring, and the length of your cutover window. An on-site assessment produces a fixed scope, and an honest quote follows from that, which is why we quote after inspection rather than from a phone call.
    Can a panel be retrofitted without stopping production?Some of it, but not all of it. A replacement panel can be built, programmed, and tested offline while your line keeps running, which covers most of the work. The final cutover, where field wiring moves from old to new, requires the equipment to be de-energized and locked out. That is why cutovers are scheduled into weekends or planned shutdown windows.
    Should I retrofit my panel or replace it completely?Look at the enclosure and the wiring first. If the enclosure is sound and the field wiring tests clean, an in-place rebuild that replaces the aging components usually makes sense. If there is rust, heat damage, no spare space, or wiring you cannot trust, a shop-built replacement panel is the safer path. A proper assessment settles this before any money goes into parts.
    Will my existing PLC program survive a retrofit?If the PLC stays, the program stays, and it gets backed up before anyone touches the panel. If the PLC is obsolete and being migrated, the logic is converted to the new platform, typically in ladder logic or another IEC 61131-3 language, then tested against the machine’s known sequence before cutover. Either way the as-found program is archived, so there is always a way back.

    Bedford Industrial Automation
    © 2026 – All Rights Reserved : Bedford Industrial Automation Inc. (CANADA) · 551 Ferdinand Blvd, Suite 2, Dieppe NB E1A 7G1This site respects your system’s reduced-motion setting. With it on, video and animation are replaced by still images and all content remains. To see the video version, turn animations back on in your device’s accessibility settings.